Run Diagnostic
Runs a diagnostic test.
Targets
-diagnostic (Quick|Config|Security|FW)
: Run a specific test by supplying its name. By default all tests are run. One of:Quick
- This test verifies that the persistent memory module host mailbox is accessible and that basic health indicators can be read and are currently reporting acceptable values.Config
- This test verifies that the BIOS platform configuration matches the installed hardware and the platform configuration conforms to best known practices.Security
- This test verifies that all modules have a consistent security state. It’s a best practice to enable security on all modules rather than just some.FW
- This test verifies that all modules of a given model have consistent firmware installed and other firmware modifiable attributes are set in accordance with best practices.Note that the test does not have a means of verifying that the installed firmware is the optimal version for a given Intel Optane DC memory module model - just that it’s been consistently applied across the system.
dimm (DimmIDs)
: Runs a diagnostic test on specific modules by supplying one or more comma-separated DimmIDs. The default is to run the specified tests on all manageable modules. Only valid for theQuick
diagnostic test.
Examples
Run all diagnostics
Run the quick check diagnostic on module 0x0001
Return Data
Each diagnostic generates one or more log messages. A successful test generates a single log message per module indicating that no errors were found. A failed test might generate multiple log messages each highlighting a specific error with all the relevant details. Each log contains the following information: